Model 398-6HT is an individually heated tube bath with 6 independently controlled test positions. The key factor in designing the 398 series is to give the operator the benefit of having complete control of the equipment.
No longer will the operator have to run all the test positions and samples at the same time and at the same temperature. The operator now has individual control of the temperature and testing time for every single position. For example, if you have model 398-6HT, you can run two samples at 40C at 9:00 a.m., while prepping and then running two additional samples at 60C at 9:15 a.m., all without interrupting the other tests. This instrument prevents an idle test position from being wasted.
The time and temperature parameters are all controlled via touch panel. This simplifies the contol process and makes it more intuitive.
|
|
|
390-4
|
Manual Liquid Bath for Rust Testing, 4 positions. D665, D3603, D5534, NACE (specify) |
390-6
|
Manual Liquid Bath for Rust Testing, 6 positions. D665, D3603, D5534, NACE (specify) |
396-6A
|
Manual Individually Heated Tube Bath for Rust Testing, 6 positions. D665, NACE (specify) |
396-6B
|
Manual Individually Heated Tube Bath for Rust Testing, 6 positions. D3603, D5534 |
396-4A
|
Manual Individually Heated Tube Bath for Rust Testing, 4 positions. D665, NACE (specify) |
396-4B
|
Manual Individually Heated Tube Bath for Rust Testing, 4 positions. D3603, D5534 |
|
L636-1
|
Polishing device with chuck (115 Volts)
|
L636-2
|
Polishing device with chuck (230 Volts)
|
RS-35
|
Holding chuck (for polishing test specimen. Spare)
|
RS-36
|
400 mL beaker for D665, D3603, D5534, each
|
RS-36N
|
400 mL beaker for NACE test, each
|
RS-37
|
Beaker cover (PMMA) for D665, NACE, each
|
RS-37A
|
Beaker cover (PMMA) for Lawler D665, NACE Automatic Units, each
|
RS-37B
|
Beaker cover (PTFE) for D665, each for Procedure C (heavier than water fluids)
|
RS-37C
|
Beaker cover (PTFE) for Lawler D665 Automatic Units, each for Procedure C
|
RS-38
|
Steel test specimen for D665, each
|
RS-39
|
Plastic holder (PMMA) for D665 specimen, each
|
RS-40
|
Teflon holder (PTFE) for D665 specimen, each
|
RS-41
|
Rusting test apparatus assembly with specimens for D3606 (Fig. 1)
|
RS-42
|
Beaker cover for D3603 and D5534, each
|
RS-43
|
Horizontal disc test specimen for D3603, each
|
RS-44
|
Vertical test specimen for D3603 (includes specimen, washer, cap), each
|
RS-45
|
Clear plastic stirrers' shield for 4 position baths
|
RS-46
|
Clear plastic stirrers' shield for 6 position baths
|
RS-47
|
NACE Air purging system of electrical enclosure with differential pressure gauge & remote air blower for reduced fire danger NOT Certified Explosion proof
|
RS-48
|
Paddle and Shaft, D665, NACE. Spare
|
RS-49
|
Paddle and Shaft, D665, NACE. Spare
|
RS-50
|
FTM 791-5315 Paddle and Shaft
|
RS-51
|
Auxiliary Stirrer Blade for ASTM D665 Procedure C (heavier than water fluids)
|
RS-52
|
Steel test specimen for D5534, each
|
RS-53
|
Water beaker for D5534 Part B, each
|
SCC-10
|
Silicon carbide abrasive cloth, J-weight 100-grit for NACE (50 sheets)
|
SCP-24
|
Silicone carbide paper 240-grit (50 sheets)
|
SCP-15
|
Silicone carbide paper 150-grit (50 sheets)
|
|
|
|
|
|
|
|